A Contact (NO)
Operating pressure:1.7MPa OFF
Reset pressure: 0.9MPa ON
Contact capacity
AC DC250V/3A
Operation Rating
Max. Discharge time:99sec
Min. Interval time:1min
Working Viscosity Range
68〜1000mm2/S (50Hz)
Reservoir Capacity
1.8ℓ、3ℓ (plastic) 3ℓ、4ℓ、8ℓ (sheet metal)
Weight
1.8ℓReservoir:3.3kg 3ℓReservoir:4kg(plastic)
APPLICATION:
Model
Model
Part Number
AMO-II-150S-1
202067
AMO-II-150S-1-3
202069
AMO-II-150S-1-P
202071
AMO-II-150S-1-P-3
202073
Model
Part Number
AMO-II-150S-2
202068
AMO-II-150S-2-3
202070
AMO-II-150S-2-P
202072
AMO-II-150S-2-P-3
202074
Directions for use
●
This pump unit requires a separate control circuit to operate.
●
Do not remove the oil strainer to keep the pump clear of foreign matter.
●
Replace or clean the suction filter at least once a year. Click here to view the service list.
●
Oil viscosity varies with oil temperature. Be sure to use oil within the working viscosity range. Refer to the viscosity table.
●
Do not use any special additive-contained oil, water soluble oil and solvent.
●
Periodically check the oil in the reservoir for impurities. Replace it, if necessary, with fresh oil immediately. Be sure to clean the reservoir before oil change.
●
Make sure that proper voltage and pressure are proper.
●
Do not overtighten the discharge joint. Refer to the tightening torque table.
●
Low-oil viscosity versions are available. Contact us for information.
●
For system planning information, Contact us.
Document
Pump Drawing
Wiring digram
Dimensional Drawing
Improper handling can result in a death or serious injury.
Electrical shock may be received under certain conditions.。
Family-owned and operated with over 60 years of experience.
We provide machinery sales, repair, rigging, and also supply tooling and lubrication products to shops throughout Fresno and the Central Valley.