Incorporating an energy-saving motor, economical and realizing intermittent lubrication by simply turning the power ON.
Automatic intermittent pump incorporating a small motor,hence an economical model.
Widely used for small machines in many industries.
Specifications
Pump | Discharge Volume | 0.2〜1.0ml/stroke 1.5〜2.5ml/stroke 2.5〜5.5ml/stroke |
|
---|---|---|---|
Discharge Pressure | 0.3MPa | ||
Motor (Other voltages available.) |
Voltage / Current | AC100Vφ1/50mA AC200Vφ1/25mA (50Hz) AC100Vφ1/42mA AC200Vφ1/18mA (60Hz) |
|
Output | 3W Synchronous Motor | ||
Emergency Detection | Oil level | ||
Oil level switch |
|
||
|
|||
Operation Rating | Continuous | ||
Working Viscosity Range | 32〜1300mm2/S | ||
Reservoir Capacity | 1.8l、3l (plastic) 3l、4l、8l (sheet metal) | ||
Weight | 1.8kg (With 1.8l Reservoirs ) | ||
Protection class | IP54 (CE Approved type) |
APPLICATION:
Model
Replacement Motor Model
Interval | 3min. | 6min. | 15min. | 30min. | 60min. | 120min. | ||
---|---|---|---|---|---|---|---|---|
Motor RPM (50Hz) | 20 | 10 | 4 | 2 | 1 | 1/2 | ||
Replacement Motor Model | 100V | Model | M-A1 | M-B1 | M-C1 | M-D1 | M-E1 | M-F1 |
Part Number | 521210 | 521194 | 521193 | 520062 | 520061 | 520060 | ||
200V | Model | M-A2 | M-B2 | M-C2 | M-D2 | M-E2 | M-F2 | |
Part Number | 521328 | 521196 | 521195 | 520067 | 520066 | 520065 |
Model
Model | Part Number |
---|---|
MMXLⅢ CE-1A-1 | 367001 |
MMXLⅢ CE-1A-1L | 367055 |
MMXLⅢ CE-1A-2 | 367007 |
MMXLⅢ CE-1A-2L | 367061 |
MMXLⅢ CE-1B-1 | 367002 |
MMXLⅢ CE-1B-1L | 367056 |
MMXLⅢ CE-1B-2 | 367008 |
MMXLⅢ CE-1B-2L | 367062 |
MMXLⅢ CE-1C-1 | 367003 |
MMXLⅢ CE-1C-1L | 367057 |
MMXLⅢ CE-1C-2 | 367009 |
MMXLⅢ CE-1C-2L | 367063 |
MMXLⅢ CE-1D-1 | 367004 |
MMXLⅢ CE-1D-1L | 367058 |
MMXLⅢ CE-1D-2 | 367010 |
MMXLⅢ CE-1D-2L | 367064 |
MMXLⅢ CE-1E-1 | 367005 |
MMXLⅢ CE-1E-1L | 367059 |
MMXLⅢ CE-1E-2 | 367011 |
MMXLⅢ CE-1E-2L | 367065 |
MMXLⅢ CE-1F-1 | 367006 |
MMXLⅢ CE-1F-1L | 367060 |
MMXLⅢ CE-1F-2 | 367012 |
MMXLⅢ CE-1F-2L | 367066 |
Model | Part Number |
---|---|
MMXLⅢ CE-2A-1 | 367019 |
MMXLⅢ CE-2A-1L | 367073 |
MMXLⅢ CE-2A-2 | 367025 |
MMXLⅢ CE-2A-2L | 367079 |
MMXLⅢ CE-2B-1 | 367020 |
MMXLⅢ CE-2B-1L | 367074 |
MMXLⅢ CE-2B-2 | 367026 |
MMXLⅢ CE-2B-2L | 367080 |
MMXLⅢ CE-2C-1 | 367021 |
MMXLⅢ CE-2C-1L | 367075 |
MMXLⅢ CE-2C-2 | 367027 |
MMXLⅢ CE-2C-2L | 367081 |
MMXLⅢ CE-2D-1 | 367022 |
MMXLⅢ CE-2D-1L | 367076 |
MMXLⅢ CE-2D-2 | 367028 |
MMXLⅢ CE-2D-2L | 367082 |
MMXLⅢ CE-2E-1 | 367023 |
MMXLⅢ CE-2E-1L | 367077 |
MMXLⅢ CE-2E-2 | 367029 |
MMXLⅢ CE-2E-2L | 367083 |
MMXLⅢ CE-2F-1 | 367024 |
MMXLⅢ CE-2F-1L | 367078 |
MMXLⅢ CE-2F-2 | 367030 |
MMXLⅢ CE-2F-2L | 367084 |
Model | Part Number |
---|---|
MMXLⅢ CE-5A-1 | 367037 |
MMXLⅢ CE-5A-1L | 367091 |
MMXLⅢ CE-5A-2 | 367043 |
MMXLⅢ CE-5A-2L | 367097 |
MMXLⅢ CE-5B-1 | 367038 |
MMXLⅢ CE-5B-1L | 367092 |
MMXLⅢ CE-5B-2 | 367044 |
MMXLⅢ CE-5B-2L | 367098 |
MMXLⅢ CE-5C-1 | 367039 |
MMXLⅢ CE-5C-1L | 367093 |
MMXLⅢ CE-5C-2 | 367045 |
MMXLⅢ CE-5C-2L | 367099 |
MMXLⅢ CE-5D-1 | 367040 |
MMXLⅢ CE-5D-1L | 367094 |
MMXLⅢ CE-5D-2 | 367046 |
MMXLⅢ CE-5D-2L | 367100 |
MMXLⅢ CE-5E-1 | 367041 |
MMXLⅢ CE-5E-1L | 367095 |
MMXLⅢ CE-5E-2 | 367047 |
MMXLⅢ CE-5E-2L | 367101 |
MMXLⅢ CE-5F-1 | 367042 |
MMXLⅢ CE-5F-1L | 367096 |
MMXLⅢ CE-5F-2 | 367048 |
MMXLⅢ CE-5F-2L | 367102 |
Directions for use:
-Oil viscosity varies with oil temperature. Be sure to use oil
within the working viscosity range. Refer to the viscosity
table. (P.237)
-Do not use any oil containing special additives, water
soluble oil, or solvent.
-Periodically check the oil in the reservoir for impurities.
-Replace with fresh oil immediately, if necessary. Be sure to
clean the reservoir before oil adding new oil.
-Make sure that proper voltage is applied.
-Do not over tighten the discharge joint. Refer to the tightening torque table. (P.251)
-Do not press the discharge volume adjusting knob down
by force.
-Adjust discharge volume only when the piston is fully
relaxed (The knob is at the lowest position.).
-Replace the suction filter at least once a year.
-Do not remove the oil fill strainer in order to keep the pump
clear of foreign matter.
-Check the direction of motor rotation. Change U and W
of the three-phase connection to change the direction of
rotation.
-Do not place the pump sideways or upside down.