|
Specifications |
|
|
|
Power consumption |
maximum 3W |
Discharge time |
199sec |
Interval time |
199min |
Emergency output |
(x,x terminal)ON at low oil level and/or abnormal pressure
Contact capacity : AC250V, DC30V |
Option |
(1) Oil level switch (Between o-o terminals)
(2) Pressure switch (Between P-Pterminals)
Use a switch with the minimum capacity of 12V, 10mmA
Do not connect to (NC) terminal (V)
Terminal (V) is used only when the controller is equipped with the condensor for motor. |
|
|
Lamp indication |
|
|
|
POWER |
Green lamp is ON when power is turned ON |
INT(INTERVAL) |
Yellow lamp is ON during interval |
DIS(DISCHARGE) |
Green lamp is ON during discharge |
EMG(EMERGENCY) |
Red lamp is ON at low oil level and / or abnormal pressure. |
TIMER:Digital switch |
INTERVAL 099min
DISCHARGE 099sec |
ALARM RESET |
Press the button to reset. |
INSTANT FEED
(Manual discharge) |
When pressed, it starts discharging and completes its discharge cycle set by the timer. |
|
|
Part Number |
|
|
|
Part Number |
Model |
Power voltage |
Rated load |
Circit protector |
300041 |
ME2-T |
Single-phase AC100V/110V
50/60Hz±10% |
Single-phase 75W
motor or equal load |
2A |
300042 |
ME2-T |
Single-phase AC200V220V
50/60Hz±10% |
1A |
300043 |
ME2-T |
Three-phase AC200V/220V
50/60Hz±10% |
Three-phase 200W
motor or equal load |
|
|
Operation flow chart |
|
|
|
Terminal block wiring diagram |
|
|
|
Dimensional drawing |
|
|
|